| Fire Deficiencies |
|
This Nursing home:
9
|
|
WI
State Average:
5
|
|
U.S. Average:
4
|
|
WI
Deficiencies Range
1–19
|
Updated April 18, 2013. |
How well this home met National Fire Protection Agency standards in the most recent inspection.
September 14, 2012 Fire Inspection
| Nursing Home Did Not Have: |
Possible or Actual Harm |
Residents Affected |
Date Fixed |
| Proper power supply for life support equipment. |
Low
|
Many
|
10/25/2012 |
| A fire alarm system that can be heard throughout the facility. |
Low
|
Many
|
11/1/2012 |
| Properly installed electrical wiring and equipment. |
Low
|
Some
|
9/27/2012 |
| Corridors or aisles that are unobstructed and are at least 8 feet in width. |
Low
|
Some
|
9/14/2012 |
| At least two remote exits on each floor or fire section of the building. |
Low
|
Some
|
9/17/2012 |
| Corridor and hallway doors that block smoke. |
Low
|
Some
|
11/1/2012 |
| Heating and ventilation systems that have been properly installed according to the manufacturer's instructions. |
Low
|
Few
|
10/5/2012 |
| Corridors that are separated from use areas by walls constructed to limit the passage of smoke. |
Low
|
Few
|
9/17/2012 |
| Automatic sprinkler systems that have been maintained in working order. |
Low
|
Few
|
9/14/2012 |
August 31, 2011 Fire Inspection
| Nursing Home Did Not Have: |
Possible or Actual Harm |
Residents Affected |
Date Fixed |
| Proper backup exit lighting. |
Low
|
Some
|
10/21/2011 |
| Properly installed electrical wiring and equipment. |
Low
|
Some
|
10/6/2011 |
| Properly protected cooking facilities. |
Low
|
Some
|
Not Corrected |
| Properly sized and located compartments to protect residents from smoke. |
Low
|
Some
|
10/4/2011 |
| Proper medical gas storage and administration areas. |
Low
|
Some
|
10/6/2011 |
| Properly maintained smoke detectors. |
Low
|
Some
|
10/21/2011 |
| Approved construction type or materials. |
Low
|
Some
|
10/12/2011 |
| A two-hour-resistant firewall separation. |
Low
|
Some
|
9/30/2011 |
| Automatic sprinkler systems that have been maintained in working order. |
Low
|
Some
|
10/2/2011 |
| Corridor and hallway doors that block smoke. |
Low
|
Some
|
9/2/2011 |
| Emergency lighting that can last at least 1 1/2 hours. |
Low
|
Some
|
10/21/2011 |
| Exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector. |
Low
|
Some
|
10/6/2011 |
| Heating and ventilation systems that have been properly installed according to the manufacturer's instructions. |
Low
|
Some
|
10/6/2011 |
| Posted "no-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed. |
Low
|
Some
|
10/6/2011 |
| Rooms that can be unlocked from inside without a key. |
Low
|
Some
|
10/6/2011 |
| Signs that state that exit doors are to be kept closed. |
Low
|
Some
|
9/14/2011 |
| Smoke barrier doors that can resist smoke for at least 20 minutes. |
Low
|
Some
|
10/6/2011 |
| Special areas constructed so that walls can resist fire for one hour or an approved fire extinguishing system. |
Low
|
Some
|
10/6/2011 |
| Walls that prevent smoke from passing through and would resist fire for at least one hour. |
Low
|
Some
|
10/6/2011 |
| Protected exits that allow the resident to escape the building. |
Low
|
Few
|
10/4/2011 |
September 14, 2010 Fire Inspection
| Nursing Home Did Not Have: |
Possible or Actual Harm |
Residents Affected |
Date Fixed |
| Weekly inspections and monthly testing of generators. |
Low
|
Many
|
9/20/2010 |
| Walls that prevent smoke from passing through and would resist fire for at least one hour. |
Low
|
Some
|
9/16/2010 |
| Special areas constructed so that walls can resist fire for one hour or an approved fire extinguishing system. |
Low
|
Some
|
9/14/2010 |
| Smoke barrier doors that can resist smoke for at least 20 minutes. |
Low
|
Some
|
9/15/2010 |
| Proper medical gas storage and administration areas. |
Low
|
Some
|
9/14/2010 |
| Properly protected cooking facilities. |
Low
|
Some
|
9/14/2010 |
| Other fire safety features required by fire safety codes. |
Low
|
Some
|
9/27/2010 |
| Properly installed electrical wiring and equipment. |
Low
|
Some
|
9/14/2010 |
| Corridor and hallway doors that block smoke. |
Low
|
Some
|
9/16/2010 |
Note: Because of differences in calculation, all data may not match those shown on Nursing Home Compare, a website run by the federal Centers for Medicare & Medicaid Services. CMS has approved the U.S. News methodology.
Last updated
April 18, 2013.