Geneva Lake Manor

Fire Safety

Fire Deficiencies
This Nursing home: 7
WI State Average: 5
U.S. Average: 4
WI Deficiencies Range 1–20
Updated April 12, 2014.

How well this home met National Fire Protection Agency standards in the most recent inspection.

November 14, 2013 Fire Inspection

Nursing Home Did Not Have: Possible or Actual Harm Residents Affected Date Fixed
Exits that are free from obstructions and can be used at all times.
Low
Many
12/14/2013
An approved installation, maintenance and testing program for fire alarm systems.
Low
Many
12/14/2013
Corridor and hallway doors that block smoke.
Low
Some
12/14/2013
Exits that are accessible at all times.
Low
Some
12/14/2013
Properly constructed windows in hallway walls or doors.
Low
Some
12/14/2013
Properly installed electrical wiring and equipment.
Low
Some
12/14/2013
A two-hour-resistant firewall separation.
Low
Some
12/14/2013

August 02, 2012 Fire Inspection

Nursing Home Did Not Have: Possible or Actual Harm Residents Affected Date Fixed
Weekly inspections and monthly testing of generators.
Low
Many
9/2/2012

May 25, 2011 Fire Inspection

Nursing Home Did Not Have: Possible or Actual Harm Residents Affected Date Fixed
Properly installed electrical wiring and equipment.
Low
Some
6/20/2011
Proper medical gas storage and administration areas.
Low
Some
6/20/2011
A fire alarm system that can be heard throughout the facility.
Low
Some
6/20/2011
Special areas constructed so that walls can resist fire for one hour or an approved fire extinguishing system.
Low
Some
6/20/2011
Walls that prevent smoke from passing through and would resist fire for at least one hour.
Low
Some
6/20/2011
Signs that state that exit doors are to be kept closed.
Low
Some
6/20/2011
A two-hour-resistant firewall separation.
Low
Some
6/20/2011
Automatic sprinkler systems that have been maintained in working order.
Low
Some
6/20/2011
Corridor and hallway doors that block smoke.
Low
Some
6/20/2011
Corridors that are separated from use areas by walls constructed to limit the passage of smoke.
Low
Some
6/20/2011
Exits that are accessible at all times.
Low
Some
6/20/2011
Heating and ventilation systems that have been properly installed according to the manufacturer's instructions.
Low
Some
6/20/2011
Properly constructed windows in hallway walls or doors.
Low
Some
6/10/2011

Note: Because of differences in calculation, all data may not match those shown on Nursing Home Compare, a website run by the federal Centers for Medicare & Medicaid Services. CMS has approved the U.S. News methodology.

Last updated April 12, 2014.