Health Care Center Lucy Corr

Fire Safety

Fire Deficiencies
This Nursing home: 16
VA State Average: 4
U.S. Average: 4
VA Deficiencies Range 1–16
Updated April 12, 2014.

How well this home met National Fire Protection Agency standards in the most recent inspection.

October 25, 2013 Fire Inspection

Nursing Home Did Not Have: Possible or Actual Harm Residents Affected Date Fixed
A written emergency evacuation plan.
Low
Some
Not Corrected
Walls that prevent smoke from passing through and would resist fire for at least one hour.
Low
Some
Not Corrected
Special areas constructed so that walls can resist fire for one hour or an approved fire extinguishing system.
Low
Some
Not Corrected
Smoke barrier doors that can resist smoke for at least 20 minutes.
Low
Some
Not Corrected
Record of quarterly fire drills for each shift under varying conditions.
Low
Some
Not Corrected
Properly installed electrical wiring and equipment.
Low
Some
Not Corrected
Other fire safety features required by fire safety codes.
Low
Some
Not Corrected
Heating and ventilation systems that have been properly installed according to the manufacturer's instructions.
Low
Some
Not Corrected
Exits that are accessible at all times.
Low
Some
Not Corrected
An approved automatic sprinkler system connected to the fire alarm system.
Low
Some
Not Corrected
An approved installation, maintenance and testing program for fire alarm systems.
Low
Some
Not Corrected
Corridor and hallway doors that block smoke.
Low
Some
Not Corrected
A two-hour-resistant firewall separation.
Low
Some
Not Corrected
Automatic sprinkler systems that have been maintained in working order.
Low
Some
Not Corrected
An externally vented heating system.
Low
Few
Not Corrected
Weekly inspections and monthly testing of generators.
Very Low
Many
Not Corrected

November 07, 2012 Fire Inspection

Nursing Home Did Not Have: Possible or Actual Harm Residents Affected Date Fixed
An approved installation, maintenance and testing program for fire alarm systems.
Low
Many
12/18/2012
Smoke barrier doors that can resist smoke for at least 20 minutes.
Low
Many
12/18/2012
Properly installed electrical wiring and equipment.
Low
Few
12/18/2012

October 31, 2011 Fire Inspection

Nursing Home Did Not Have: Possible or Actual Harm Residents Affected Date Fixed
Proper stairway enclosures and vertical shafts.
Low
Few
12/15/2011
Properly installed electrical wiring and equipment.
Low
Few
12/15/2011
Portable fire extinguishers.
Low
Few
12/15/2011
Corridor and hallway doors that block smoke.
Low
Few
12/15/2011
Smoke barrier doors that can resist smoke for at least 20 minutes.
Low
Few
12/15/2011
Rooms that can be unlocked from inside without a key.
Low
Few
12/15/2011

Note: Because of differences in calculation, all data may not match those shown on Nursing Home Compare, a website run by the federal Centers for Medicare & Medicaid Services. CMS has approved the U.S. News methodology.

Last updated April 12, 2014.


Search Nursing Homes

Nearby Nursing Homes