Country Village Care

Fire Safety

Fire Deficiencies
This Nursing home: 9
TX State Average: 5
U.S. Average: 4
TX Deficiencies Range 1–21
Updated April 18, 2013.

How well this home met National Fire Protection Agency standards in the most recent inspection.

February 29, 2012 Fire Inspection

Nursing Home Did Not Have: Possible or Actual Harm Residents Affected Date Fixed
An approved installation, maintenance and testing program for fire alarm systems.
Low
Many
3/9/2012
Automatic sprinkler systems that have been maintained in working order.
Low
Many
4/26/2012
Proper medical gas storage and administration areas.
Low
Few
4/26/2012
Walls that prevent smoke from passing through and would resist fire for at least one hour.
Low
Few
4/26/2012
Exits that are accessible at all times.
Low
Few
3/1/2012
Emergency lighting that can last at least 1 1/2 hours.
Low
Few
3/8/2012
Corridor and hallway doors that block smoke.
Low
Few
3/1/2012
Exits that are free from obstructions and can be used at all times.
Low
Few
4/26/2012
Special areas constructed so that walls can resist fire for one hour or an approved fire extinguishing system.
Low
Few
3/2/2012

January 13, 2011 Fire Inspection

Nursing Home Did Not Have: Possible or Actual Harm Residents Affected Date Fixed
Portable fire extinguishers.
Low
Few
2/25/2011
An externally vented heating system.
Low
Few
2/11/2011
Automatic sprinkler systems that have been maintained in working order.
Low
Few
1/20/2011
Exits that are accessible at all times.
Low
Few
2/25/2011
Special areas constructed so that walls can resist fire for one hour or an approved fire extinguishing system.
Low
Few
2/11/2011
Walls that prevent smoke from passing through and would resist fire for at least one hour.
Low
Few
2/25/2011

January 07, 2010 Fire Inspection

Nursing Home Did Not Have: Possible or Actual Harm Residents Affected Date Fixed
An approved automatic sprinkler system connected to the fire alarm system.
Low
Many
3/8/2010
Automatic sprinkler systems that have been maintained in working order.
Low
Many
3/8/2010
A complete sprinkler system with alarm system connection.
Low
Many
3/8/2010
A fire alarm system that can be heard throughout the facility.
Low
Some
3/8/2010
Walls that prevent smoke from passing through and would resist fire for at least one hour.
Low
Some
1/8/2010
Corridor and hallway doors that block smoke.
Low
Few
1/8/2010
Emergency lighting that can last at least 1 1/2 hours.
Low
Few
1/25/2010
Smoke barrier doors that can resist smoke for at least 20 minutes.
Low
Few
3/8/2010
Weekly inspections and monthly testing of generators.
Very Low
Many
3/8/2010

Note: Because of differences in calculation, all data may not match those shown on Nursing Home Compare, a website run by the federal Centers for Medicare & Medicaid Services. CMS has approved the U.S. News methodology.

Last updated April 18, 2013.