| Fire Deficiencies |
|
This Nursing home:
8
|
|
TX
State Average:
5
|
|
U.S. Average:
4
|
|
TX
Deficiencies Range
1–21
|
Updated April 18, 2013. |
How well this home met National Fire Protection Agency standards in the most recent inspection.
April 11, 2012 Fire Inspection
| Nursing Home Did Not Have: |
Possible or Actual Harm |
Residents Affected |
Date Fixed |
| Exits that are accessible at all times. |
Low
|
Many
|
5/4/2012 |
| An approved installation, maintenance and testing program for fire alarm systems. |
Low
|
Many
|
5/31/2012 |
| Exits that are free from obstructions and can be used at all times. |
Low
|
Many
|
4/12/2012 |
| Properly located and lighted "exit" signs. |
Low
|
Some
|
5/31/2012 |
| Proper construction of ducts through walls designed to prevent smoke passage. |
Low
|
Some
|
4/20/2012 |
| Corridor and hallway doors that block smoke. |
Low
|
Some
|
4/27/2012 |
| Other fire safety features required by fire safety codes. |
Very Low
|
Many
|
5/31/2012 |
| Portable fire extinguishers. |
Very Low
|
Some
|
4/13/2012 |
April 13, 2011 Fire Inspection
| Nursing Home Did Not Have: |
Possible or Actual Harm |
Residents Affected |
Date Fixed |
| Proper construction of ducts through walls designed to prevent smoke passage. |
Low
|
Few
|
5/14/2011 |
| Automatic sprinkler systems that have been maintained in working order. |
Very Low
|
Many
|
5/14/2011 |
March 25, 2010 Fire Inspection
| Nursing Home Did Not Have: |
Possible or Actual Harm |
Residents Affected |
Date Fixed |
| A complete sprinkler system with alarm system connection. |
Low
|
Many
|
5/7/2010 |
| Walls that prevent smoke from passing through and would resist fire for at least one hour. |
Low
|
Many
|
5/7/2010 |
| Proper medical gas storage and administration areas. |
Low
|
Many
|
5/7/2010 |
| Proper construction of ducts through walls designed to prevent smoke passage. |
Low
|
Many
|
5/7/2010 |
| An approved automatic sprinkler system connected to the fire alarm system. |
Low
|
Some
|
5/7/2010 |
| Corridor and hallway doors that block smoke. |
Low
|
Some
|
5/7/2010 |
| Properly protected cooking facilities. |
Low
|
Some
|
5/7/2010 |
| Automatic sprinkler systems that have been maintained in working order. |
Very Low
|
Many
|
5/7/2010 |
| Properly installed electrical wiring and equipment. |
Very Low
|
Some
|
5/7/2010 |
| Heating and ventilation systems that have been properly installed according to the manufacturer's instructions. |
Very Low
|
Some
|
5/7/2010 |
Note: Because of differences in calculation, all data may not match those shown on Nursing Home Compare, a website run by the federal Centers for Medicare & Medicaid Services. CMS has approved the U.S. News methodology.